9. National Pediatric Urology Congress

View Abstract

Video Room - 7

A New Technique For Difficult Urethral Catheterizations

HM Ürekli, MM Utanğaç, F Çelik, ME Balkan, N Kılıç
Uludag University faculty of Medicine Depatment of Pediatric Surgery and Pediatric Urology

AİM: Providing the catheterization procedure through the sensor guide without deteriorating the tip structure of the material to be used for urethral catheterization

METHODS: The needle was removed from the lumen from the first hole at the tip of the catheter. The sensor guide 18G was pushed through the needle tip. Then the needle was pulled back. The sensor guide was inserted into the lumen of the catheter from the hole near the tip of the catheter. Thus, the urethral catheter can be easily advanced through the sensor guide to the waist without deformity. The same procedure was applied in the feeding, foley catheter and aspiration catheter.

CONCLUSION: The techniques described can easily be used in difficult urethral catheterization.

Zorlu Üretral kateterizasyonlarda Yeni Bir Teknik

HM Ürekli, MM Utanğaç, F Çelik, ME Balkan, N Kılıç
Uludağ Üniversitesi Tıp Fakültesi Çocuk Cerrahisi AD Çocuk Ürolojisi BD

AMAÇ: Üretral kateterizasyon için kullanılacak malzemenin uç yapısı bozulmadan kateterizasyon işlemini sensör guide üzerinden sağlamak

YÖNTEM: 18G iğne ucu kateterin ucundan lümene doğru geçirildi. Kateterin uç kısmındaki ilk delikten iğne lümen dışına alındı. Sensör guide 18G iğne ucunun içinden geçirildi. Daha sonra iğne geri çekildi. Sensör guide kateterin uc kısmına yakın yerdeki delikten kateterin lümeninin içine alındı. Böylelikle üretral kateter ucu deforme olmadan rahatlıkla sensör guide üzerinden mesaneye doğru ilerletilebilir. Aynı işlem Feeding, foley sonda ve aspirasyon kateteri içinde uygulandı.

SONUÇ: Zorlu üretral kateterizasyonlarda tariflenen teknik kolaylıkla kullanılabilir.

Close